Battery Room Hydrogen Gas Leak Detector Specification

  • Voltage
  • 110-215 Volt (v)
  • Material
  • MS
  • Usage
  • Industrial
  • Operate Method
  • Manual
  • Use
  • Industrial
  • Operating Mode
  • Manual
 

Battery Room Hydrogen Gas Leak Detector Trade Information

  • Minimum Order Quantity
  • 2 Pieces
  • Supply Ability
  • 10 Pieces Per Week
  • Delivery Time
  • 3 Week
  • Main Domestic Market
  • All India
  • Certifications
  • Expo Proof Exd IIA/B/C
 

About Battery Room Hydrogen Gas Leak Detector

Battery Room Hydrogen Gas Leak Detector


Battery Room Hydrogen Gas Leak Detector Model GD 200 is available for monitoring gas leakage This modular gas leak alarm system can be expanded to desired number of channels for continual monitoring of single or multi locations for leak of smoke toxic or explosive gases This instrument is apt for monitoring for high ambient gas conditions It is ideal for toxic gas monitoring of clean rooms or gas free areas where there is a very less chances of the presence of other interfering gases however specific gas filters can be incorporated with the sensors in order to minimize the cross sensitivity to unwanted gases This gas leakage detecting system is gonogo type with adjustable 3 level alarms It can be panel mounted or on a standard rack Every modulechannel is a complete individual instrument that comes with a visual alarm and relays outputs except from regulated power supply that is provided by the master power supply board


Special Features


Modular Construction

Single Point Monitoring System

Toxic Explosive Gas LPG PNG CNG Vapor Smoke

3 Level concentration fault alarm

Power LED

Visual Audible Alarm Facility

Explosion Proof Enclosure

24 V DC or 230V AC50 Hz

Isolated Relays

Self Integrity Check Utility

High Alarm RED Very High Alarm RED Malfunction Amber

Dimensions 13530Xnoof channels W X 133 H X 240 L

Technical Specification


Type


Portable


Detectable gasesparameters


O2 flammable gases vapors and hydrogen


Electronics processor


Analog


Power supply


Rechargeable battery 12 x 4 D size with charger


Display


Numeric LCD 1999 digits


Alarm


Audio visual


Sensor Technology


EC CC TCD


Resolution


1 PPM 1 LEL 1 VV


Accuracy


2 for FS 05 O2


Response time


Less than 15 seconds


Operating temperature


0 55 C


Sampling


Manual aspiration


Housing case


Cast aluminum


Included Accessories


Leather case PVC tube with filter Aspirator

4 numbers rechargeable battery with charger


Dimensions


150 L x 100 W x 115 H mm



Reliable Gas Detection for Industrial Safety

This hydrogen gas leak detector is specially engineered for industrial battery rooms, where hydrogen emissions can pose explosion risks. Its rugged MS and Ex-proof construction ensures reliable operation in harsh environments, providing continuous monitoring and timely alerts. The manual operating mode gives users greater control over device activation, fostering a safer work environment.


Energy-Efficient and Versatile Design

Consuming just 3 Watts of power and functioning across a voltage range of 110-215V, this detector offers exceptional energy efficiency and compatibility with various industrial power systems. Its 230V AC 50Hz power supply ensures easy integration into standard industrial setups, making it a flexible choice for many facilities.

FAQ's of Battery Room Hydrogen Gas Leak Detector:


Q: How does the Battery Room Hydrogen Gas Leak Detector work?

A: The detector operates by manually activating its sensor system, which monitors the air for traces of hydrogen gas. When a potential leak is detected, it alerts operators, allowing them to take immediate action to prevent unsafe conditions.

Q: What materials are used in the construction of this detector?

A: This detector is constructed using explosion-proof materials and mild steel (MS), ensuring durability and safety in hazardous industrial environments such as battery rooms.

Q: When should the detector be installed in an industrial setting?

A: Installation should be done prior to operating the battery room or any area where hydrogen gas may accumulate, to provide early warning and maintain ongoing safety.

Q: Where is the ideal location to place the hydrogen gas leak detector?

A: The detector should be installed at the highest point in the battery room, since hydrogen is lighter than air and accumulates near the ceiling. This maximizes detection capability and prevents hazardous buildup.

Q: What is the process for using the detector?

A: Operators activate the detector manually to begin gas monitoring. The system then continuously checks for hydrogen gas leaks and provides alerts if dangerous concentrations are detected.

Q: How does using this detector benefit industrial operations?

A: Employing this detector enhances workplace safety by providing timely warnings of hydrogen leaks, reducing the risk of explosions, equipment damage, and personnel harm, while maintaining compliance with safety regulations.

Q: What industries commonly use this hydrogen gas leak detector?

A: This device is widely used in industrial settings, especially in battery storage rooms, power plants, and other facilities where hydrogen gas is a byproduct or poses a safety concern.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Gas Leak Detector Category

EZ-SENSE Combustible Gas Leak Detector

EZ-SENSE Combustible Gas Leak Detector

Price 18000.0 INR / Piece

Minimum Order Quantity : 2 Pieces, Piece

Temperature : 55 Celsius (oC)

Operating Voltage : 3.6 V DC Volt (V)

Operating Mode : Single Handed

Humidity : 95%

Pocket Gas Monitor Gd-100

Pocket Gas Monitor Gd-100

Price 17500 INR

Minimum Order Quantity : 5

Temperature : 50 Deg. Cel.

Operating Voltage : 3.6V Volt (V)

Operating Mode : Automatic