Back to top
UV/IR Test Lamp TL 205

UV/IR Test Lamp TL 205

100000.00 - 110000.00 INR/Piece

Product Details:

  • Number of Specimens 1 (per operation)
  • Mounting Type Handheld
  • Operating Voltage 220V AC
  • Measuring Range Emission in UV/IR spectrum
  • Specimen Size Standard UV/IR sensor size
  • Automation Grade Manual
  • Response Time Immediate (on switch ON)
  • Click to View more
X

UV/IR Test Lamp TL 205 Price And Quantity

  • 100000.00 - 110000.00 INR/Piece
  • 1 Piece

UV/IR Test Lamp TL 205 Product Specifications

  • Manual operation
  • 0C to 50C
  • Single test at a time
  • 5% to 95% RH (non-condensing)
  • Test Lamp
  • 220V AC, 50Hz
  • 50 Hz
  • Standard sensitivity for sensor functional check
  • Verification of flame detector response
  • Detects UV and IR sensor response
  • No display (indicator LED for operation)
  • Handheld, Compact, Lightweight, Easy operation
  • Testing UV and IR flame detectors
  • Manual
  • Manual/Test lamp ON-OFF by switch
  • Immediate (on switch ON)
  • Manual
  • Standard UV/IR sensor size
  • 1.2 kg
  • Emission in UV/IR spectrum
  • Handheld
  • 220V AC
  • 1 (per operation)

UV/IR Test Lamp TL 205 Trade Information

  • Telegraphic Transfer (T/T)
  • 10 Piece Per Year
  • 2 Months
  • Eastern Europe, Western Europe, Middle East, Africa, Asia
  • All India
  • Intrinsic Safe

Product Description

UV IR Test Lamp, TL 205 model is a compact, hand-held instrument that can test the response of the flame detector. This user-friendly instrument produces UV and IR radiation to verify the response of the flame detection system. This instrument doesnt need for an open flame. It can be used in hazardous areas. The testing procedure must be carried out by two people, one will operate the test lamp and the other one will set up the controllers and monitor the systems response to the lamp. 


USAGE:

 

  • Turn on the flame detection system
  • Switch ON the system and it will bling repeatedly after 30 seconds
  • Direct the brightest part of light towards the detecting part and wait for flame detector operation
  • If a flame detection system does not work properly, repeat all steps again with closer access to flame detector
  • Press operation switch 'OFF'       
SPECIFICATION
  • Type:   Portable , Table Top , Hand Held
  • Features:   Suitable to test UR & IR flame detector
  • Power Supply :   230 V AC , 50 Hz adapter
  • Enclosure:  Anodized Aluminum
  • Range:   Up to 5 mtrs
  • Response Time:  2-3 msec


Technical Details 



Reliable Testing for Flame Detectors

The TL 205 Test Lamp delivers accurate and immediate simulation of UV and IR emissions for verifying flame detector functionality. Its portable, lightweight, and robust build makes it indispensable for engineers and safety professionals working with fire detection systems. Manual operation allows controlled testing at various angles, ensuring full flexibility in test scenarios.


Safe and User-Friendly Operation

Designed with user safety as a priority, the lamp features an insulated ABS casing, a secure push button switch, and an LED indicator for clear status feedback. The manual mode enables careful handling throughout each test, minimizing risks associated with high-voltage devices. Its compact form enhances portability and ease of use.

FAQs of UV/IR Test Lamp TL 205:


Q: How does the TL 205 Test Lamp verify UV/IR flame detector responses?

A: The TL 205 emits a controlled combination of UV and IR signals to simulate the presence of a flame. This tests whether detectors respond appropriately by triggering their sensing mechanisms when exposed to its signals.

Q: What specimens and sensor sizes can the TL 205 accommodate during testing?

A: The device is designed to test one standard-sized UV or IR flame detector at a time, ensuring precise functional checks for industry-standard sensors.

Q: When should the TL 205 UV/IR Test Lamp be used?

A: It should be used during routine maintenance, commissioning, or troubleshooting of UV/IR flame detector installations to confirm sensor functionality and response accuracy.

Q: Where is the TL 205 typically operated for flame detector testing?

A: The lamp is well-suited to both field and laboratory settings, wherever flame detectors require diagnostic testing. Its compact design and easy portability support flexible use locations.

Q: What is the process for operating the TL 205 Test Lamp?

A: Operation is manual; position the lamp towards the detector, press the push button to activate, observe the detectors response, and monitor the LED indicator for operational status. The lamp can be angled as needed for optimal testing.

Q: What benefits does the TL 205 offer over automated test systems?

A: The TL 205 provides direct, hands-on control and immediate feedback, making it ideal for quick sensor verification without the complexity of automated systems. Its safety features and ease of use enhance efficiency and reduce risk during testing.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Flame Detector' category