Cookie Img
Back to top
Send SMS    Call Me Free Offline
      Home » Products » Wireless Gas Transmitter Receiver

      Wireless Gas Transmitter Receiver

      Wireless Gas Transmitter Receiver
      Wireless Gas Transmitter Receiver
      Product Code : RC 253
      Trade Information
      • Main Export Market(s)
      • Asia, South America, Eastern Europe, Western Europe, Middle East, Africa
      • Main Domestic Market
      • All India
      Product Description

      Wireless Transmitter Receiver

      The gas sensor transmitter functions by transmitting radio wave frequencies to the receiver Model RC 253.  HNL Wireless gas Detection system is designed to monitor gas concentrations in potentially hazardous environments without the use of wires /cables between the transmitter and receiver unit.
      Linearization, calibration & reconfiguration of the transmitter can be performed remotely.

      Specifications:

      •     Up to 8 Channels can be monitored
      •     Alarms for Low & High and Specific Fault
      •     Specific Sensor as Per the Measuring Gas, Range & Application
      •     Sample Conditioning System Offered As Per Application
      •     Complete Automatic Operation
      •     8 Characters 2 line LCD Display messages
      •     Self Diagnostic Check Facility
      •     A Mere Four Key to Operate the Complete Instrument
      •     It's Versatile Modular Design Permits Configuration and Up-Gradation to Suit Specific Needs of Customer in Selection of Gases to be measured
      •     Calibration: Manual, On command in microprocessor based system through PC (RS-232)
      •     Comes along with I-Analytics Analyzer GUI (Graphical User Interface)
      •     Reports generation through GUI (Excel, PPT & PDF formats)
      •     Graphical representation of values with respect to time
      •     Online monitoring
      •     Offline data uploading
      •     On Alarm any electrical device / equipment controller through PC· 2 / 8 Channel Receiver accepts radio transmission from Model IANA-2XXX Series
      •     Output: 4 - 20mA, RS232/485, LAN (Ethernet Optional), GSM/GPRS Modem (optional), Relays
      •     Sensor & sampling: Gas Range & Application dependent.
      •     Display: 16X2 / 20X4 LCD Display
      •     Power Supply: 12- 24 VDC
      •     Ambient Temp: 0-50°C
      •     Enclosure: High Impact Plastic
      •     Optional: Flush on Panel/Table top
      •     Warm uptime: Analysis Detector dependent
      •     Alarms: Two Level (selectable range)
      •     Calibration: Manual, On command in microprocessor based system through PC (RS-232)
      •     Reports generation through GUI (Excel, PPT & PDF formats)
      •     Graphical representation of values with respect to time
      •     Online monitoring
      •     Offline data uploading
      •     On Alarm any electrical device / equipment controller through PC.


       


      HNL SYSTEMS PVT. LTD.

      Contact Us

      ( *represents compulsory fields )

      Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.